The scanner waited for four frames when shown a single one. Its chunk assembler
was written for SB1, which the generator always cuts into exactly four frames,
and its fallback branch claims any non-JSON string longer than 100 characters —
which a 151-character SBQ2 invitation is. A complete invitation was filed as
chunk 1 of 4, and the scan never finished.
SBQ2 payloads are now recognised as complete before any assembly runs, in both
the text and raw-byte forms, and the hard-coded frame count is marked as
belonging to SB1 so it is not read as a general rule.